TECHNICAL SPECIFICATIONS
| GENERATOR SET SPECIFICATIONS | |
| PRIME POWER RATING (KVA) | 15 |
| KW | 12 |
| PHASE | 1P/3P |
| RATED CURRENT (A) | 65/21 |
| GENSET MODEL | HG15KVA |
| VOLTAGE | 230V(1P)/ 415V(3P) |
| POWER FACTOR | 0.8 |
| FUEL CONSUMPTION @100% | 3.1 litres/hour |
| FUEL CONSUMPTION @75% | 2.54 litres/hour |
| FUEL CONSUMPTION @50% | 1.8 litres/hour |
| BATTERY STARTING VOLTAGE | 12 VDC |
| ENGINE SPECIFICATIONS | HARISON ENGINE |
| ENGINE MODEL | HG1P2R2M |
| CAPACITY OF ENGINE | 3168 cc |
| RATED OUTPUT @100% LOAD | 29 BHP |
| NUMBER OF CYLINDERS | 4 |
| NO. OF STROKES | 4 |
| BORE*STROKE | 98*105 |
| RATED SPEED | 1500 |
| TYPE OF ASPIRATION | Naturally Aspirated |
| COOLING SYSTEM | LIQUID COOLED |
| COOLANT CAPACITY | 8 LITERS |
| TYPE OF GOVERNER | Mechanical / Electronic |
| BATTERY CAPACITY | 80 AH |
| OVERLOAD CAPACITY | 10% Overloading is allowed after 10 Hours of continuous running |
| OIL SUMP CAPACITY | 6.2 LITRES |
| ALTERNATOR SPECIFICATIONS | |
| MAKE | LEROY SOMER / MECCALTE / STAMFORD |
| RATING | 15 KVA |
| POWER FACTOR | 0.8 |
| TYPE | Brushless-IP 23 with AVR |
| VOLTAGE, VOLTS | 230 V (1P) / 415 V (3P) |
| RATED SPEED | 1500 rpm |
| FREQUENCY, HZ | 50 Hz |
| VOLTAGE REGULATIONS | VG 3 |
| CLASS OF INSULATION | H-Class |
| CONTROL PANEL | With both Inbuilt ATS/AMF and Manual Options |
| WAVE FORM DISTORTION/TOTAL HARMONIC DISTORTION | No Load<1.5% Non distortion Balanced Linear Load 5% |
| TELEPHONIC HARMONIC FACTOR | <2% |
| ACOUSTIC SPECIFICATIONS | |
| NOISE LEVEL | <75DBA @1meter distance |
| LENGTH | 1800 |
| WIDTH | 900 |
| HEIGHT | 1250 |
| FUEL TANK CAPACITY | 90 Liters |
| APPROX NET WEIGHT | 740 KG |







Rohit sharma –